Search results for " MEMS"
showing 9 items of 9 documents
The SESAMO early warning system for rainfall-triggered landslides
2016
The development of Web-based information systems coupled with advanced monitoring systems could prove to be extremely useful in landslide risk management and mitigation. A new frontier in the field of rainfall-triggered landslides (RTLs) lies in the real-time modelling of the relationship between rainfall and slope stability; this requires an intensive monitoring of some key parameters that could be achieved through the use of modern and often low-cost technologies. This work describes an integrated information system for early warning of RTLs that has been deployed and tested, in a prototypal form, for an Italian pilot site. The core of the proposed system is a wireless sensor network coll…
Drug delivery from the oral cavity: focus on a novel mechatronic delivery device
2007
Dental drug delivery systems have been used for a long time, in particular for the local therapy of diseases affecting the oral cavity. Research today concentrates on the design of formulations to increase their retention time. Even today, however, prosthetic devices incorporating drug delivery are rarely used. Mainly, they are focused on prophylaxis and the release of antibacterial agents. However, as buccal delivery, because of its undeniable advantages, has become popular for systemic drug delivery, and prolonged well-controlled release has been identified as beneficial, especially for chronic diseases, a new class of delivery systems is evolving: highly miniaturized computerized deliver…
Real time assessment of hand-arm vibration system based on capacitive MEMS accelerometers
2012
Vibrations are a well known potential cause of health diseases and therefore constitute a main concern for the safety of workers in a large number of activities. In order to prevent health hazards, national and international institutions have issued laws and directives which establish recommended limits to the workers' exposure to vibrations during operations. Consequently, if the amount of adsorbed vibration exceeds the allowable daily limits the worker has to stop his job. Recent wireless sensing and communicating technologies can effectively be employed for such purpose, allowing to develop monitoring customized devices at affordable cost which could be easily employed during the workers…
A LiDAR Prototype with Silicon Photomultiplier and MEMS Mirrors
2018
In this paper, we present a low cost prototype of a Time-Of-Flight (TOF) LiDAR system, employing a SiPM as photo detector and MEMS mirrors in order to steer the nanosecond pulsed optical beam with a scanning angle of +/-6°. Preliminary TOF measurements have been performed both indoor and outdoor to test the limits of the system.
A Novel System for Measuring Damaging Impacts on Table Olives
2015
The consumer today demands high quality products; fruit with defects or in poor condition generate dissatisfaction and a consequent reduction in consumption. In recent years, interesting systems have been used (i. e. "artificial fruit") in order to identify the cause of damage during mechanical harvesting and/or post-harvest operations. In this paper, the authors present a new system designed to measure the impacts received by table olives in the processing stages from harvesting to packaging. The device is an instrumented sphere designed and implemented by the Agricultural Mechanics Section of the Department of Agricultural and Forest Sciences, University of Palermo, Italy. It contains a t…
Reverberation reduction in capacitive micromachined ultrasonic transducers (CMUTs) by front-face reflectivity minimization
2015
Abstract Front-face acoustic reflectivity of ultrasonic imaging transducers, due to acoustic impedance mismatch with the propagation medium, may cause reverberation phenomena during wideband pulse-echo operation. Front-face reflectivity may be reduced by promoting the transmission of the echoes, received from the medium, to the transducer backing, and by maximizing the mechanical-to-electrical energy conversion and dissipation by tuning the electrical load impedance connected to the transducer. In Capacitive Micromachined Ultrasonic Transducers (CMUTs), the energy transfer from the medium to the backing is very low due to the large impedance mismatch between the medium and the transducer su…
Urban MEMS based seismic network for post-earthquakes rapid disaster assessment
2014
Abstract. In this paper, we introduce a project for the realization of the first European real-time urban seismic network based on Micro Electro-Mechanical Systems (MEMS) technology. MEMS accelerometers are a highly enabling technology, and nowadays, the sensitivity and the dynamic range of these sensors are such as to allow the recording of earthquakes of moderate magnitude even at a distance of several tens of kilometers. Moreover, thanks to their low cost and smaller size, MEMS accelerometers can be easily installed in urban areas in order to achieve an urban seismic network constituted by high density of observation points. The network is being implemented in the Acireale Municipality (…
La rete museale intradiocesana di Erice
2014
L'esperienza di valorizzazione e musealizzazione dei beni mobili e immobili di pertinenza ecclesiastica di Erice maturata all'interno del progetto culturale diocesano "La Montagna del Signore". Nel contributo vengono illustrati i percorsi di fruizione e i metodi gestionali consolidati da oltre un decennio.
A novel device for assessing the health risk caused by hand-arm vibrations in olives harvesting
2012
The mechanization of olive harvesting is very important both to reduce the costs of production and to assure the oil quality because the manual harvest does not allow to operate at the right time and also need a long period to be completed. The use of portable shakers, that are spreading more than others typologies, can give a solution to the problem. However, the use of such equipment may involve risk of exposure to hand-transmitted vibration. The aim of this study was to assess the level of exposure to hand-arm vibration of the operators using portable shakers (reference standards UNI EN ISO 5349-1:2004, Italian Low Decree 81/2008). The research presented here concerns the definition of a…